ST-S-CF

Ceramic-fibre barrier sheet

Ceramic-fibre facing for cell and module pads. Same rule: a layer inside a tested assembly.

Battery module context
Sheet stack
Converted parts

Typical values for this family

Ceramic-fibre facing. Temperature points below are as stated on the family table.

PropertyTypical figureNote
FacingCeramic fibreCustom thickness typically 1–10 mm
Maximum service800 °C as statedFamily table
Flame ratingUL94 V-0As stated
Density300 ± 30 kg/m³As stated
λ at 25 °C≤ 0.023 W/(m·K)GB/T 10295 as stated
λ at 300 °C≤ 0.036 W/(m·K)GB/T 10294 as stated
λ at 500 °C≤ 0.072 W/(m·K)GB/T 10294 as stated
Hydrophobicity> 98 %As stated
FormatSheet / die-cutGeometry from the buyer’s drawing

Values on this page are typical figures as stated for this family. They are not SHINETON-guaranteed field results. Specify only from the current Technical Data Sheet for the supplied grade.

Operating conditions, acceptance criteria and system design stay with the buyer’s engineer. SHINETON matches the grade, issues documents and agrees inspection and shipment scope.

System build

1. Geometry

Buyer drawing.

2. Grade

Do not substitute ST-S-FG or ST-S-PAN without the sheet.

3. Validation

Pack-level test stays with the buyer.