ST-C-RC

Radiative-cooling coating

Water-based finish for roofs, tank crowns and plant envelopes where solar load and radiative cooling are specified together.

SHINETON ST-C-RC 20 L pail
Roof and tank-crown duty
Plant envelope context

Typical values for this family

Radiative-cooling family. Reflectance and emittance stay on this card. Indoor °C and kWh savings are not published here.

PropertyTypical figureNote
ColourWhite, tintableWhite is the optical baseline
Solar reflectance≥ 0.90As stated on the family card
Hemispherical emissivity≥ 0.90As stated on the family card
Normal emissivity≥ 0.90As stated on the family card
Net radiative cooling power≥ 20 W/m²As stated on the family card
Solid content69.0 ± 2.0 %120 °C, 1 h as stated
Water resistanceNo defect after 96 h immersionFamily card
Alkali resistanceNo defect within 48 hFamily card
Adhesion≤ Level 1As stated
pH7.0–9.0As supplied
Typical mid-coat2–6 mmOften over a primer and, where specified, an insulation mid-coat
ApplicationRoll, spray or brushSubstrate clean and dry; 5–80 °C

Values on this page are typical figures as stated for this family. They are not SHINETON-guaranteed field results. Specify only from the current Technical Data Sheet for the supplied grade.

Operating conditions, acceptance criteria and system design stay with the buyer’s engineer. SHINETON matches the grade, issues documents and agrees inspection and shipment scope.

System build

1. Primer

Anti-corrosive primer on carbon steel, stainless or alloy — typically ≤ 150 µm.

2. Thermal mid-coat

Where a build is specified, 2–6 mm energy-saving mid-coat.

3. Radiative finish

ST-C-RC plus a hydrophobic top film if the duty needs it.