ST-C-HOT

Industrial heat-loss coating

Water-based aerogel mid-coat for hot pipe, equipment and tanks where wrap insulation is too thick or hard to terminate.

SHINETON ST-C-HOT 20 L pail
Coating check in the lab
Typical hot-equipment duty

Typical values for this family

Energy-saving industrial coating family. Figures below are the published typicals for this duty. The dated TDS governs the supplied lot.

PropertyTypical figureNote
ColourWhite, tintableFinish colour sits on the topcoat if specified
Density0.57 ± 0.02 g/cm³As stated on the family card
Long-term service≤ 180 °CContinuous duty
Short peakNear 200 °CDuration is named on the issued TDS
Thermal conductivity≤ 0.038 W/(m·K)Typical as stated for this family
Bonding≥ 4AAs stated on the family card
Water resistanceNo defect after 96 h immersionAs stated on the family card
Fire performanceB2 as statedCoating film
VOC≤ 80 g/LAs supplied
Recommended mid-coat2–8 mm dryPrimer < 0.5 mm · topcoat < 0.5 mm
ApplicationAirless spray or bladeSubstrate clean and dry; 5–80 °C; RH preferably ≤ 85 %

Values on this page are typical figures as stated for this family. They are not SHINETON-guaranteed field results. Specify only from the current Technical Data Sheet for the supplied grade.

Operating conditions, acceptance criteria and system design stay with the buyer’s engineer. SHINETON matches the grade, issues documents and agrees inspection and shipment scope.

System build

1. Substrate

Steel or primed metal. Remove loose rust, oil and condensation.

2. Mid-coat

ST-C-HOT in passes to the specified dry thickness.

3. Finish

Compatible topcoat where weather or colour is required.