ST-C-COLD

Cold-service coating

Water-based mid-coat for chilled pipe, refrigerant lines and cold tanks where condensation and heat gain are the duty.

SHINETON ST-C-COLD 20 L pail
Cold or dual-temp line context
Packaged coating pails

Typical values for this family

Cold-insulation coating family. Condensation control is a system result (thickness + climate + finish), not a standalone guarantee.

PropertyTypical figureNote
ColourWhite, tintableTopcoat carries colour if specified
Density0.55 ± 0.02 g/cm³As stated on the family card
Service range−40 to 150 °CLong-term as stated
Thermal conductivity≤ 0.040 W/(m·K)Typical as stated for this family
Bonding≥ 4AAs stated on the family card
Waterproof rating< 5 as statedFamily card
Fire performanceB2 / B1 as statedCoating film
VOC≤ 100 g/LAs supplied — different cap from ST-C-HOT
Recommended mid-coat2–8 mm dryPrimer < 0.5 mm · topcoat < 0.5 mm
ApplicationAirless spray or bladeSubstrate clean and dry; 5–80 °C; RH preferably ≤ 85 %

Values on this page are typical figures as stated for this family. They are not SHINETON-guaranteed field results. Specify only from the current Technical Data Sheet for the supplied grade.

Operating conditions, acceptance criteria and system design stay with the buyer’s engineer. SHINETON matches the grade, issues documents and agrees inspection and shipment scope.

System build

1. Substrate

Clean, dry metal. Repair and prime where corrosion is the first risk.

2. Mid-coat

ST-C-COLD to the dry thickness calculated for the climate.

3. Finish

Weatherable topcoat on outdoor lines and tanks.