ST-B-FG

Glass-fibre aerogel blanket

Flexible wrap for pipe, equipment and irregular geometry. Jacketed after the wrap.

SHINETON silica aerogel blanket roll
Wrap on a process line
Roll storage

Typical values for this family

Glass-fibre blanket family. Conductivity below uses the factory felt figure at 25 °C where that card exists; the handbook band is listed beside it.

PropertyTypical figureNote
ColourWhiteAs supplied
Maximum operating temperature650 °CMid-temperature wrap grade as stated
Thermal conductivity≦ 0.021 W/(m·K) at 25 °CFactory felt figure. Handbook band 0.016–0.020 W/(m·K)
Permanent linear change≥ −2.0 as statedOn heating, family card
Water absorption (WP)≤ 1.0 % volumetric · ≤ 5 % mass at 50 °C / 95 % RH / 96 hFamily card
Hydrophobicity≥ 98 %WP grade as stated
CombustionGrade A as statedInorganic wrap
Density180 ± 20 kg/m³As stated on the family card
Compression≥ 40 kPa at 10 % · ≥ 90 kPa at 25 % · resilience ≥ 90 %Family card
Vibration mass loss≤ 1 %Family card
Cited standardsGB/T 34336 · ASTM C1728As named on the family card
FormRolls, sheets, converted partsJacket required in service

Values on this page are typical figures as stated for this family. They are not SHINETON-guaranteed field results. Specify only from the current Technical Data Sheet for the supplied grade.

Operating conditions, acceptance criteria and system design stay with the buyer’s engineer. SHINETON matches the grade, issues documents and agrees inspection and shipment scope.

System build

1. Fit

Cut and wrap. Butt or lap on straight pipe; segmented elbows.

2. Layers

Overlap seams. Tie or band each layer.

3. Jacket

Metal or specified cladding. This page is not the install spec.